Home > ELECTRICAL > ROUGH ELECTRICAL > FUSES & BREAKERS > CIRCUIT BREAKERS - ARC FAULT
Sort By:
1
HomeLine HOM120CAFIC Arc Fault Combination Circuit Breaker HomeLine HOM115CAFIC Arc Fault Combination Circuit Breaker GE THQL Arc Fault Combination Circuit Breaker
Single-pole 1" combination CAFCI circuit breaker is designed for arc-fault, overload and short-circuit protection of an electrical system. Designed to detect arcs that are caused by damaged, aged, or improperly used wires or cords and to disconnect the power. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. White push to test button. 10kA interrupting rating. Rated for 120 VAC. Meets Canadian Electrical code. Carded. Single-pole 1" combination CAFCI circuit breaker is designed for arc-fault, overload and short-circuit protection of an electrical system. Designed to detect arcs that are caused by damaged, aged, or improperly used wires or cords and to disconnect the power. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. White push to test button. 10kA interrupting rating. Rated for 120 VAC. Meets Canadian Electrical code. Carded. Provides ARC fault, parallel, ground, series, overload and short circuit protection. Required for bedroom receptacles effective January 1, 2002. Plug in design with color-coded screws and dual function test button. 120/240 volt. 1" space per breaker.
GE THQL Arc Fault Combination Circuit Breaker MES Q115AFC Arc Fault Combination Miniature Circuit Breaker MES Q120AFC Arc Fault Combination Miniature Circuit Breaker
Provides ARC fault, parallel, ground, series, overload and short circuit protection. Required for bedroom receptacles effective January 1, 2002. Plug in design with color-coded screws and dual function test button. 120/240 volt. 1" space per breaker. Plug-in, combination type CAFCI circuit breaker, complies with the requirements for both branch/feeder and outlet circuit CAFCIs. Required on January 1, 2008 by 2005 NEC, combination type CAFCI circuit breakers must be placed on bedroom power and lighting circuits. Protects downstream branch circuit wiring and cord sets and power-supply cords. Provides ARC fault, overload and short circuit protection. UL listed. Protects against worn electrical insulation or damaged wire, misapplied or damaged plug in appliances and equipment, and loose electrical connections. 2 LEDs appear for 5 seconds each time the CAFCI is turned on, up to 30 days after the last trip to indicate last known trip condition. One LED means arcing fault. Two LEDs means arcing fault to ground. 10kA interrupting rating. UL Listed, 120 volt AC. Wire range 14 - 8 AWG. 1" space, 120 volt. Plug-in, combination type CAFCI circuit breaker, complies with the requirements for both branch/feeder and outlet circuit CAFCIs. Required on January 1, 2008 by 2005 NEC, combination type CAFCI circuit breakers must be placed on bedroom power and lighting circuits. Protects downstream branch circuit wiring and cord sets and power-supply cords. Provides ARC fault, overload and short circuit protection. UL listed. Protects against worn electrical insulation or damaged wire, misapplied or damaged plug in appliances and equipment, and loose electrical connections. 2 LEDs appear for 5 seconds each time the CAFCI is turned on, up to 30 days after the last trip to indicate last known trip condition. One LED means arcing fault. Two LEDs means arcing fault to ground. 10kA interrupting rating. UL Listed, 120 volt AC. Wire range 14 - 8 AWG. 1" space, 120 volt.
Square D QO120CAFIC Type QO Arc Fault Combination Circuit Breaker Square D QO115CAFIC Type QO Arc Fault Combination Circuit Breaker Eaton BR115CAFA Type BR Arc Fault Combination Circuit Breaker
Combination CAFCI 3/4" single-pole circuit breaker, designed for overload and over-current protection of an electrical system. Thermal-magnetic tripping mechanism. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. Visi-Trip indicator to identify which circuit is out in the load center. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. 10kA interrupting rating. Uses one space per breaker. 120 volt AC. UL Listed. Carded. Combination CAFCI 3/4" single-pole circuit breaker, designed for overload and over-current protection of an electrical system. Thermal-magnetic tripping mechanism. Designed to detect arcs that are caused by damaged, aged or improperly used wires or cords and to disconnect the power. Visi-Trip indicator to identify which circuit is out in the load center. With Time-Saver Diagnostics, advanced trip indication technology, identifying the type of fault that last occurred. 10kA interrupting rating. Uses one space per breaker. 120 volt AC. UL Listed. Carded. Plug-on combination type arc fault circuit breakers, 10,000 amperes interrupting capacity. Combination type arc fault circuit interrupter includes all of the protection offered by the branch feeder AFCI (mitigation of parallel arcing faults in the complete circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. Parallel arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load.
Eaton BR120CAFA Type BR Arc Fault Combination Circuit Breaker BREAKER CMB AFCI 1P 15A 10KAIC BREAKER CMB AFCI 1P 20A 10KAIC
Plug-on combination type arc fault circuit breakers, 10,000 amperes interrupting capacity. Combination type arc fault circuit interrupter includes all of the protection offered by the branch feeder AFCI (mitigation of parallel arcing faults in the complete circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. Parallel arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load. Combination AFCI 15 amp single-pole breaker, 10 kAIC, 120 Vac #14-4 wire size. Automatically senses hot wire-to-ground faults and shuts off the power. LED diagnostics auto-monitoring function provides periodic automatic testing of GFCI. Combination AFCI 15 amp single-pole breaker, 10 kAIC, 120 Vac #14-4 wire size. Automatically senses hot wire-to-ground faults and shuts off the power. LED diagnostics auto-monitoring function provides periodic automatic testing of GFCI.
BREAKER 15A1P 120V DUAL FUNCTN BREAKER 20A1P 120V DUAL FUNCTN BREAKER AFCI/GFCI 1P 15A
BREAKER AFCI/GFCI 1P 15A
Our Price: $56.31
Detects when current is "leaking" somewhere outside its intended path. Should the DFCI trip, the yellow LED Indicates the last known trip condition by illuminating LED for 5 seconds each time the DFCI is turned on for up to 30 days. Self-test feature. UL Listed. 3.3" height x 1" width x 3" depth, .479 lb. Detects when current is "leaking" somewhere outside its intended path. Should the DFCI trip, the yellow LED Indicates the last known trip condition by illuminating LED for 5 seconds each time the DFCI is turned on for up to 30 days. Self-test feature. UL Listed. 3.3" height x 1" width x 3" depth, .479 lb. Dual function circuit breaker. Plug-in for Siemens load centers. Combines GFCI and AFCI protection against both arc faults and ground faults. Self-Test and lockout feature. LED trip indicator. 10,000 amps interrupting capacity. HACR and SWD Rated. Used in kitchen and laundry circuits. Wire range #14 - #8 AWG. UL Listed.
BREAKER AFCI/GFCI 1P 20A      BREAKER 1P 15A AFGF DUAL FUNC BREAKER 1P 20A AFGF DUAL FUNC
BREAKER AFCI/GFCI 1P 20A
Our Price: $56.31
Dual function circuit breaker. Plug-in for Siemens load centers. Combines GFCI and AFCI protection against both arc faults and ground faults. Self-Test and lockout feature. LED trip indicator. 10,000 amps interrupting capacity. HACR and SWD Rated. Used in kitchen and laundry circuits. Wire range #14 - #8 AWG. UL Listed. Easy-to-read trip codes through LEDs and a clear test button. Ability to reset the breaker in the field and eliminate trip history. Lower power consumption allows the circuit breaker to produce less heat in high ambient areas. Short-body configuration creates easy installation by maximizing space inside the loadcenter. Easy-to-read trip codes through LEDs and a clear test button. Ability to reset the breaker in the field and eliminate trip history. Lower power consumption allows the circuit breaker to produce less heat in high ambient areas. Short-body configuration creates easy installation by maximizing space inside the loadcenter.
BRKR DUAL AF/GF 1P 15A PLG NEU BREAKER DUAL AF/GF 1P 20A     Eaton CHFCA115 Type CH Arc Fault Circuit Breaker
BREAKER DUAL AF/GF 1P 20A
Our Price: $58.81
Combination AFCI 15 amp single-pole breaker, 10 kAIC, 120 Vac #14-4 wire size. Automatically senses hot wire-to-ground faults and shuts off the power. LED diagnostics auto-monitoring function provides periodic automatic testing of GFCI. Combination AFCI 15 amp single-pole breaker, 10 kAIC, 120 Vac #14-4 wire size. Automatically senses hot wire-to-ground faults and shuts off the power. LED diagnostics auto-monitoring function provides periodic automatic testing of GFCI. Plug-on combination type arc fault circuit breakers, 10,000 amperes interrupting capacity. Combination type arc fault circuit interrupter includes all of the protection offered by the branch feeder AFCI (mitigation of parallel arcing faults in the complete circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. Parallel arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load.
Eaton CHFCA120 Type CH Arc Fault Circuit Breaker
Plug-on combination type arc fault circuit breakers, 10,000 amperes interrupting capacity. Combination type arc fault circuit interrupter includes all of the protection offered by the branch feeder AFCI (mitigation of parallel arcing faults in the complete circuit, including connected cords). In addition it provides direct detection of persistent low current arcing faults down to 5 amps with associated mitigation of fire hazards in the cords connected to the outlets. Parallel arcing faults can occur from line to neutral or line to ground. These arcing faults are in parallel with the load and produce the most energy of all arcing faults. The current level of low current arcing faults is limited by the load.
   
 
1